#Reporting
Many papers and vendors say that one deep-learning architecture is the best for a pathology task. Ganie et al., authors in Saudi Arabia, Türkiye and Azerbaijan, tested how far such a claim holds up when the comparison is controlled and repeated. They reported their benchmark in Frontiers in Oncology, November 2026.
Thirty-one architectures from nine model families were fine-tuned from public pretrained checkpoints under one shared downstream recipe. They were tested on two public three-class oral histopathology datasets, each trained and evaluated separately. The recipe was not tuned for each model, and the checkpoints came from different upstream training recipes that the authors say cannot be equalised retrospectively. For each model, the checkpoint with the highest validation top-1 accuracy was kept. The primary ranking measure was macro-F1, chosen because each diagnostic category contributes equally.
The first dataset has three classes: normal tissue, oral submucous fibrosis and oral squamous cell carcinoma. It holds 14,705 images from 150 patient samples. The authors found patient or tissue-slide identifiers occurring in more than one of the original released partitions. They therefore pooled the images and re-split them by patient or tissue-slide group into 105 training groups, 31 validation groups and 14 test groups. The test set had 1,290 images, of which 940 were squamous cell carcinoma. It contained one normal-tissue group, three oral submucous fibrosis groups and ten carcinoma groups.
The second public dataset has leukoplakia without dysplasia, leukoplakia with dysplasia and oral squamous cell carcinoma. It holds 3,763 patches, and the predefined 627-patch test subset was kept unchanged. Patient or lesion identifiers were not available for every patch, so patient-level independence between development and test patches could not be verified. The authors read the results as performance on a held-out patch set, not as evidence of patient-level generalisation.
The five highest-ranked models from the single-run benchmark on each dataset were repeated across five random seeds. A larger input size (384 by 384 pixels instead of 224 by 224 pixels) was tested on the leading models. These follow-up models were chosen from single-seed test rankings. The authors disclose this, call the resolution analysis exploratory, and describe the pairwise comparisons as exploratory evidence of performance proximity, not tests of superiority.
On the first dataset, the single-run leader had a macro-F1 of 0.9428, with a 95% cluster-bootstrap interval of 0.9316 to 0.9608. That interval was resampled over the 14 test groups and not over individual images. Across five seeds, the highest mean macro-F1 was 0.9348 ± 0.0110, closely followed by the single-run leader at 0.9331 ± 0.0278. The other three of the five models showed progressively lower means and larger variability. One model fell from a single-run macro-F1 of 0.9409 to a five-seed mean of 0.9050.
On the second dataset, the five leading models differed by only 0.0034 in single-run macro-F1, from 0.9003 to 0.9037. The five-seed leader there was a different model, with 0.9031 ± 0.0091. On both datasets, then, the highest five-seed mean was not the single-run leader. The authors conclude that the single-run order is one realisation of the training process and not a stable ordering of intrinsic quality.
On the first dataset, the intervals of the five leading models overlapped substantially. Every paired macro-F1 difference between the single-run leader and the other four had a 95% interval that included zero. A group-wise rank-based test across the five models was non-significant (p = 0.9312), and all four paired permutation comparisons, adjusted for multiple comparisons, gave 1.000. The authors say the analysis does not support superiority for the first-ranked single-run model. On the second dataset, a test across the five leading models was also non-significant (p = 0.9057), all adjusted macro-F1 permutation p-values were 1.000 and every paired macro-F1 interval included zero. Inference there is at patch level and is not patient-level evidence.
The 384 by 384 pixel input gave no consistent gain. The direction of change was mixed and most changes were small. One model's first-dataset mean macro-F1 fell from 0.9348 to 0.9049.
Accuracy and macro-F1 ranked models differently on the first dataset, where carcinoma made up 940 of the 1,290 test images. The authors say accuracy alone was insufficient for ranking. A much larger model had a marginally higher accuracy (0.9636) than the single-run leader (0.9620) but a lower macro-F1 (0.9330 against 0.9428).
Parameter count was a poor guide to performance. A very small network with 3.20 million parameters and 1.01 GFLOPs reached a macro-F1 of 0.9243 on the first dataset, while a model with 303.30 million parameters reached 0.9018. One model with 196.23 million parameters and 68.72 GFLOPs needed approximately 20 times as many parameters and more than 10 times the floating-point operations as the single-run leader, which had 9.83 million parameters and 6.30 GFLOPs. The authors say a smaller model may be more attractive when inference volume, memory demand or hardware availability matters more than the final one to two percentage points of class-balanced performance. Their timings cover a model forward pass only. They exclude image loading, preprocessing, data transfer and other workflow costs, so they do not represent clinical latency.
For the single-run leader on the first dataset, 1,241 of 1,290 test images were correct. Of 228 oral submucous fibrosis images, 189 were correct (recall 0.8289), and 36 of the 39 errors were called carcinoma. Carcinoma recall was 0.9957 (936 of 940). The paper does not analyse whether these errors come from a single slide group, and only three test groups were oral submucous fibrosis.
On the second dataset, the single-run leader got 573 of 627 patches correct. Of 118 leukoplakia-without-dysplasia patches, 95 were correct (recall 0.8051), and twenty-three were called dysplastic (19.5%). The authors say some wrong calls came with high model confidence, so raw confidence must not be read as diagnostic certainty. Their examples were chosen by ranking on wrong-class confidence, so they show worst cases and not how confident errors typically are. Heat-map overlays were used only qualitatively and were not validated as lesion localisation.
The authors conclude that no architecture consistently dominated both tasks. They say model selection should stress class-balanced performance, repeated-run stability, independence-aware uncertainty, computational cost and clinically relevant failure patterns rather than a single-run ranking. They call for multicentre patient-linked validation, calibration analysis and prospective reader studies with pathologists before any clinical claim.
#Interpretation
When models are nearly equal, a single-run ranking can change with the random seed. One table of ranks is therefore not evidence that one design is better than another.
When a vendor or paper says one architecture is best, it is reasonable to ask for:
- repeated runs, not a single run;
- uncertainty that respects patient or slide grouping;
- evaluation on data separate from the training patients;
- class-balanced measures, not accuracy alone;
- class-by-class errors;
- computing cost.
The errors here sat between neighbouring classes: oral submucous fibrosis called carcinoma, and leukoplakia without dysplasia called dysplastic. That is also where pathologists find the difficulty, so class-by-class results tell more than one headline figure.
A smaller model could matter where computing is limited. This paper did not test deployment, so that remains a possibility and not a finding.
For laboratories in India and elsewhere, the practical point is general. A laboratory or vendor offering an oral lesion classifier should show repeated-run results with uncertainty on the laboratory's own slides, scanners and stains. Public datasets and one shared protocol do not show local performance.
#Opinion
This is a clearly framed and carefully controlled benchmark. The authors re-split the first dataset to avoid identifier overlap, disclosed their limits and reported uncertainty at group level. The evidence is still narrow: two public datasets, one normal test group, only 14 test groups on the first dataset, and follow-up models chosen from test-informed rankings.
Non-significant tests with so few groups do not show that the models are equivalent. They show only that this study could not separate them.
Two claims in the paper run ahead of its data. The abstract says compact networks matched substantially larger ones, which cannot be shown with wide intervals and few groups. The paper also says architecture-task interaction was stronger than model capacity, which was not tested. This briefing repeats neither.
#Limits
- Only public datasets were used. There was no clinical reading study and no comparison with pathologists.
- Labels were at image or patch level, not whole-slide or patient-level diagnosis.
- The second dataset was analysed at patch level, and patient independence was not verified.
- The first dataset had only one normal test group.
- The authors re-split the first dataset, so its numbers are not comparable with earlier published results on the original split.
- The shared recipe was not tuned for each model, and the upstream checkpoints differ.
- Five seeds and the larger input size were tested only on leading models chosen from test-informed rankings.
- Only two datasets were studied.
- Timings are forward-pass only.
- Heat-map overlays were qualitative, and there was no calibration analysis.
This briefing summarises one study. It is not a validated protocol and gives no advice on patient management.
Frequently asked questions
Does this study show which AI architecture is best for oral histopathology?
No, the study did not show that any architecture is best. Across five random seeds the order of the leading models changed, their intervals overlapped, and tests across the five leading models were not significant on either dataset. The authors say no architecture consistently dominated both tasks.
Why can a single-run ranking mislead?
A single run is one realisation of the training process, so it can reflect chance as much as quality. Here the highest five-seed mean was not the single-run leader on either dataset, and one model's first-dataset macro-F1 fell from 0.9409 to a five-seed mean of 0.9050.
Could a smaller model replace a larger one in a laboratory?
Possibly, but this study did not test deployment. Parameter count was a poor guide to performance, and the authors say a smaller model may suit settings where inference volume, memory or hardware matter more than the last one to two percentage points. Their timings cover a forward pass only.
Source
https://doi.org/10.3389/fonc.2026.1957542 ↗For education and professional reference. This does not give patient-specific advice or replace professional judgement, local protocols or consultation. Editorial standards.




