# Flagging TFE3-rearranged renal carcinoma on H&E slides in under-30s: a screening aid, not a FISH substitute

> A deep learning model reading one H&E slide flagged TFE3-rearranged renal cell carcinoma in an external cohort with an AUROC of 0.932 and sensitivity of 0.893. It is a screening aid, and immunohistochemistry and FISH remain the tests of record.

Type: Briefing · Topic: Digital pathology
Published: 2026-11-27T10:03:10+00:00
Updated: 2026-11-27T10:03:10+00:00
Canonical URL: https://www.pathologistsbrief.com/article/tfe3-renal-carcinoma-he-screening
Publisher: Pathologist’s Brief
Source: https://doi.org/10.1002/cam4.72161
Author: Editor
Reviewer: Pathologist’s Brief editorial team
Review date: 2026-11-27

## Reporting

TFE3-rearranged renal cell carcinoma is a rare, aggressive subtype that mainly affects adolescents and young adults. Its marked variation in morphology can delay recognition and confirmatory testing. TFE3 immunohistochemistry is prone to pre-analytic and analytic variability, including differences in antibodies, staining platforms and scoring criteria. FISH and RNA-based assays are labour-intensive, costly and technically demanding, so they are not routinely done for all renal cell carcinomas.

Authors in China asked whether a deep learning model applied to one routine H&E whole-slide image could flag likely TFE3-rearranged tumours, so that confirmatory testing can be prioritised. Chen et al. reported the work in [Cancer Medicine, August 2026](https://doi.org/10.1002/cam4.72161).

The study was a two-centre retrospective cohort of patients younger than 30 years with renal cell carcinoma. Of 273 young patients assessed, 45 were excluded and 228 were analysed. Of these, 59 (25.9%) had a FISH-confirmed TFE3 rearrangement. The reference standard was TFE3 break-apart FISH, called positive when at least 10% of tumour nuclei showed a split signal.

The development cohort had 129 patients, 31 of them positive. The external cohort had 99 patients, 28 of them positive. One representative H&E slide per patient, the one with the highest tumour grade, was scanned and annotated by pathologists.

Two pathology foundation models were used to extract features, and an attention-based slide-level model was trained on each. The final score was the average of the two models' maximum probabilities, with a threshold of 0.5. The model was compared with three TFE3 immunohistochemistry scoring methods. The authors also report an uncertainty analysis and attention heatmaps.

In the external cohort, the area under the receiver operating characteristic curve (AUROC) was 0.932 (95% CI 0.868 to 0.978). Accuracy was 0.879, sensitivity 0.893, specificity 0.873, precision 0.735 and negative predictive value 0.954.

For the three immunohistochemistry methods in the same cohort, the AUROC ranged from 0.793 to 0.819, accuracy from 0.848 to 0.859 and sensitivity from 0.643 to 0.750. A test comparing AUROCs gave p values from 0.024 to 0.046 against each method.

Some immunohistochemistry methods were more specific and more precise than the model. One had a specificity of 0.944 and a precision of 0.818. Two others had specificity of 0.887 and 0.915, and one had a precision of 0.769. The model was more sensitive than all three.

The authors conclude that the model is an encouraging, interpretable screening tool that could help prioritise confirmatory testing and pathologist review. They state that it complements immunohistochemistry and FISH and does not replace them.

## Interpretation

An AUROC of 0.932 from one external cohort with only 28 positives, and a lower bound of 0.868, is encouraging but imprecise.

The model caught more positives than the immunohistochemistry methods, but it was not more specific than all of them. A precision of 0.735 means that not every flagged slide is a true positive. How many flags are correct also depends on how common the entity is in the population screened.

The paper does not test a workflow, turnaround time or a pathologist triage reading. The plausible use is only as a prompt to order immunohistochemistry or FISH sooner. The reference test stays the test of record.

For laboratories in India and elsewhere, FISH and RNA-based assays are not always available or affordable, so a triage aid could matter. It would need local validation on local scanners, stains and case mix. Slides that need tumour annotation add effort.

## Opinion

The question is clearly framed and useful in a rare tumour. The study has a held-out external cohort and a fair comparison against three scoring methods.

The interval is wide, though. The comparisons with immunohistochemistry rest on p values between 0.024 and 0.046, with no adjustment for multiple comparisons. Words such as "outperformed" in the abstract and "consistently outperformed" in the discussion run ahead of the data.

The paper also claims that the combined model is better than a simpler feature-fusion model. That comparison was not tested, so this briefing does not repeat it.

## Limits

The study was retrospective. With only 28 positive cases in the external cohort, estimates are imprecise. It included patients younger than 30 only, so it says nothing about older patients.

Both hospitals belong to one university group. The external cohort was held out from model development, but it is not a geographically or institutionally diverse test.

Each patient contributed one slide, and pathologist tumour annotation was needed, which limits routine use. There was no pathologist reader study. The authors say future work should frame this as a triage task. There was no adjustment for multiple comparisons.

The two foundation models were chosen from five candidates by comparing AUROC, and it is not clear which data were used for that choice. The heatmaps and the uncertainty analysis are illustrative and qualitative.

The authors call for prospective evaluation in larger, geographically diverse cohorts and for multimodal extensions. Slide data are available only on request.

This briefing summarises one study. It is not a validated protocol and gives no advice on patient management.

## Frequently asked questions

### Can the model replace TFE3 immunohistochemistry or FISH?
No. The authors describe it as a screening tool that complements immunohistochemistry and FISH. FISH was the reference standard in the study. The model could only prompt earlier confirmatory testing, and the paper did not test a clinical workflow or a pathologist triage reading.

### How did the model compare with immunohistochemistry?
The model was more sensitive, but some immunohistochemistry methods were more specific and more precise. In the external cohort, sensitivity was 0.893 for the model and 0.643 to 0.750 for the three scoring methods. Specificity of the methods reached 0.944, against 0.873 for the model.

### Why should the results be read with caution?
The external cohort held only 28 positives, so the estimates are imprecise. The AUROC interval ran from 0.868 to 0.978. Both hospitals belong to one university group, patients were younger than 30, and the comparisons with immunohistochemistry were not adjusted for multiple testing.