  1. Scenario
  2. Discussion
  3. Takeaway
  4. Source
  5. Frequently asked questions

Can p16 immunohistochemistry on a nodal core needle biopsy be relied on to reflect the p16 status of the surgical specimen?

Reveal the discussion

This is a fictional teaching scenario.

#Scenario

A cervical lymph node core needle biopsy shows metastatic squamous cell carcinoma during investigation of a suspected oropharyngeal primary. Before primary-site surgery, the reporting pathologist is asked whether p16 immunohistochemistry on the nodal core can reliably reflect the p16 status of the eventual surgical specimen.

#Discussion

Lee et al. retrospectively studied 39 patients at a single tertiary referral centre in South Korea between March 2019 and March 2024. The cohort included 35 patients with oropharyngeal squamous cell carcinoma and 4 with head and neck squamous cell carcinoma of unknown primary. Inclusion required evaluable p16 results on both ultrasound-guided nodal core and surgical specimens.

The surgical reference was the primary tumour in oropharyngeal cases and a resected metastatic cervical node in unknown-primary cases. Thus, the comparison was not uniformly between a nodal core and a primary-site resection.

Observed concordance was 100.0% (39/39; 95% confidence interval [CI], 91.0 to 100.0%). Sensitivity was 100.0% (35/35; 95% CI, 90.0 to 100.0%), and specificity was 100.0% (4/4; 95% CI, 39.8 to 100.0%). These were exact binomial intervals. The wide specificity interval reflects only 4 p16-negative cases, so complete observed agreement does not establish precise specificity.

Every included patient had metastatic squamous cell carcinoma and an evaluable p16 result at the first core session. A session included all cores obtained during the same visit, including additional passes when necessary. The mean number of cores was 1.3. This is the yield within the selected paired-evaluable cohort, not the yield among everyone initially screened.

Among the 35 oropharyngeal cases, 10 (28.6%) required more than 1 primary-site surgical session to establish carcinoma and p16 status. The mean number of surgical sessions was 1.3. Core biopsy preceded surgery in 28 patients but followed an initial surgical biopsy in 11. These different sequences prevent a direct comparison of equivalent first-line diagnostic pathways or proof that core sampling reduces repeat procedures.

No core-related complications were identified during the immediate observation period of 20 minutes. Delayed complications were not systematically assessed, so the observation does not establish their absence.

p16 was positive when strong, diffuse nuclear and cytoplasmic staining involved ≥70% of tumour cells. Other patterns, including weak, focal or patchy staining, were scored negative. Interpretation occurred in routine care without study-specific blinding to the paired result.

p16 is a surrogate for HPV-driven disease, not a direct viral assay. HPV testing varied between in situ hybridisation, PCR and IHC, limiting direct comparison of viral detection between specimen types. The authors propose HPV E6/E7 mRNA testing in future studies to confirm the findings.

The retrospective design, modest sample size, predominance of p16-positive cases and selection for paired evaluable results restrict generalisation. Lack of study-specific blinding could influence interpretation. There was no direct fine-needle aspiration comparison, and the procedural analysis was observational. The authors call for prospective multicentre comparative studies with more p16-negative cases before wider adoption, including assessment of clinical and cost effectiveness. No funding or conflicts of interest were declared.

#Takeaway

  • Nodal core p16 reflected paired surgical p16 status in this selected cohort.
  • The small negative group leaves specificity uncertain despite complete observed concordance.
  • First-session core yield and surgical session counts describe different diagnostic sequences.
  • p16 agreement does not establish equivalent HPV detection or replace the need for further validation.

#Source

Lee et al., Medicine, 2 October 2026, reported the diagnostic accuracy study discussed here.

Frequently asked questions

Was the surgical comparator always the primary tumour?

No, the surgical reference depended on the diagnostic group. It was the primary tumour in oropharyngeal carcinoma and a resected metastatic cervical lymph node in unknown-primary cases. The overall concordance therefore combines these comparisons and should not be described as exclusively nodal-core agreement with primary-site surgical tissue.

Does the study show that core biopsy prevents repeat surgery?

No, the procedural observations do not prove that core biopsy prevents repeat surgery. Some cores preceded surgery, whereas others followed an initial surgical biopsy. These were different diagnostic sequences rather than a standardised comparison, so reductions in repeated procedures or diagnostic costs require prospective evaluation before they can be claimed.

Were delayed biopsy complications excluded?

No, delayed complications were not systematically assessed. The study recorded no core-related complications during the immediate post-procedural observation period, which supports only that defined observation. Its safety findings therefore need to be read alongside the limited monitoring window rather than extended to later events that were not systematically captured.

Source