On this page
#Why look beyond a section?
Prostate glands form a spatial network of acini and ducts. Cancer changes that architecture, and glandular growth patterns underpin histological grading. A single section can hide whether apparently separate gland profiles connect through the depth of the tissue.
Laguna-Castro et al. explored direct volumetric imaging of archived tissue in The Journal of Pathology: Clinical Research, 13 October 2026. Their micro-CT workflow aimed to add architectural context while keeping the same material available for conventional examination.
Serial-section reconstruction consumes tissue and requires extensive sectioning and alignment. Optical approaches may require deparaffinisation, clearing and labelling, which can alter tissue geometry. These demands can limit research use of archived paraffin material that must stay available afterwards.
#What was scanned?
The study included 5 archived radical prostatectomy specimens. A core was retrieved from each using a punch of 2 mm diameter. The sampled regions included benign tissue and cancer representing different Gleason patterns.
After retrieval, the paraffin cores were placed in syringes and mounted directly in a commercial micro-CT scanner. No additional contrast staining or other processing preceded scanning. Near-zero manipulation therefore describes preparation after core retrieval, rather than imaging an untouched whole archival block.
#Balancing detail and scan time
Pilot optimisation selected 50 kV, which gave the strongest tissue-to-paraffin contrast among the tested voltages. Imaging used a 10× optical objective, detector binning of 2× and an isotropic voxel size of 2.47 μm. Each scan covered 360° with 1,600 projections.
The chosen exposure was 25 seconds per projection, giving a scan duration of approximately 11 hours per core. The higher-exposure reference used 75 seconds per projection and approximately 33 hours. The shorter acquisition retained interpretable gland boundaries, luminal spaces and gland-stroma interfaces.
Anisotropic diffusion was selected for denoising after quantitative comparison and visual review. It balanced preservation of gland boundaries and stromal texture, although some local detail softened. The filter with the highest numerical similarity to the reference was not the preferred visual compromise. The tested autoencoder introduced small morphological inconsistencies.
#What matched histology?
All cores subsequently underwent histological processing. Digitised haematoxylin and eosin (H&E) sections were manually matched to virtual micro-CT planes. Immunostained sections also supported structural identification.
Tissue contours, gland-rich and stromal regions, epithelial outlines, lumina, luminal concretions and fibromuscular stroma corresponded qualitatively between modalities. Micro-CT supplied architectural information, while finer cellular and molecular detail remained a strength of other imaging approaches. These images did not establish a substitute for cellular assessment on histology.
An illustrative manual segmentation separated epithelium and luminal spaces in a cancer-containing region. Structures that appeared as individual profiles in virtual sections could be followed as continuous glands, including local luminal branching.
The intact scans also gave a geometric reference before sectioning. Matched histology showed local tissue loss, tearing and expansion. Exploratory measurements suggested modest whole-core dimensional changes and more variable lumen-level changes, but none of the tested deformation measures reached conventional statistical significance.
#What remained usable?
The workflow was compatible with subsequent histology and immunohistochemistry. It therefore offers a way to relate volumetric architecture to later sections while preserving material after imaging for further histological assessment or re-archiving.
For archival research, the attraction is access to spatial gland relationships without additional contrast staining or preparation-intensive clearing. Future work proposed by the authors includes larger cohorts, systematic architectural mapping, automated segmentation, better registration and shorter acquisitions.
#Limits
This was a very small proof-of-concept cohort, not a diagnostic validation study. The architectural examples should not be generalised to particular Gleason patterns. The voxel resolution and architectural correspondence do not establish cellular diagnostic detail or grading accuracy.
Manual plane matching introduced procedural uncertainty. No beam-hardening correction or dedicated sensitivity analysis was performed, so subtle effects on apparent boundaries cannot be excluded. Deformation measurements were exploratory.
Acquisition remained lengthy, and access requires dedicated instrumentation. Molecular testing after this particular protocol was not evaluated; compatibility with downstream molecular analysis requires direct validation.
Frequently asked questions
Does near-zero manipulation mean no tissue was removed?
No, the researchers first retrieved paraffin core punches from archived specimens. The phrase applies to preparation of those cores before scanning: they were mounted without additional processing or contrast staining. The findings therefore concern intact retrieved cores, rather than direct volumetric examination of an entire untouched archival block.
Why was denoising judged visually as well as numerically?
Numerical similarity alone did not identify the preferred balance of tissue features. Visual review considered gland boundaries and stromal texture alongside noise reduction. Some methods smoothed away fine detail, while the autoencoder introduced small inconsistencies. The selected anisotropic diffusion filter still softened local detail, so denoising involved a compromise.
Can the scanned material still be used for molecular tests?
This protocol did not directly test downstream molecular compatibility. Subsequent histology and immunohistochemistry were demonstrated, but that result does not establish preservation for every later assay. The authors specifically identify direct molecular validation as future work, alongside larger cohorts and improvements to acquisition, registration and segmentation.
Source
https://doi.org/10.1002/2056-4538.70119 ↗For education and professional reference. This does not give patient-specific advice or replace professional judgement, local protocols or consultation. Editorial standards.