Tursynkozha et al., in Journal of Pathology Informatics, September 2026, report a study by researchers in Kazakhstan. Automated nuclear segmentation supports quantitative morphology, but densely packed lymphoid tissue presents low contrast between adjacent nuclei and varied nuclear shapes. Manual annotation is time-consuming and subject to observer variability.
The cohort comprised 18 lymph node specimens: 10 classical Hodgkin lymphoma, 7 non-Hodgkin lymphoma and 1 with cancer metastasis. The non-Hodgkin group included 2 marginal zone lymphoma, 2 follicular lymphoma, 1 mantle cell lymphoma, 1 chronic lymphocytic leukaemia/small lymphocytic lymphoma and 1 large B-cell non-Hodgkin lymphoma not further identified.
Each specimen was split into two portions for conventional formalin-fixed paraffin-embedded (FFPE) processing or rapidly frozen sections fixed in glyoxal (CRYO). Both were stained with haematoxylin only. Images were captured with a microscope camera at x40, rather than by whole-slide scanning.
Manual ground truth comprised 84,744 nuclei across 464 images. A subset of 50 images, comprising 25 FFPE and 25 CRYO images, was independently annotated by 2 trained histologists. Their agreement Dice was 0.8383 ± 0.0668 for FFPE and 0.8371 ± 0.0529 for CRYO, with overall agreement of 0.8377 ± 0.0596. All annotations underwent quality-control review.
The researchers evaluated an instance-segmentation model built for star-shaped nuclear outlines, used both pre-trained and custom-trained, and a larger semantic-segmentation model. FFPE and CRYO images were analysed separately. For the trained configurations, each patient was held out in turn, with training and validation confined to the remaining patients. The pre-trained configuration was evaluated without study-specific training or fine-tuning.
Mean Dice values in the Results text were:
| Configuration | FFPE | CRYO |
|---|---|---|
| Pre-trained instance model | 0.7432 | 0.7398 |
| Custom-trained instance model | 0.7354 | 0.7597 |
| Semantic model | 0.8373 | 0.8239 |
None of the FFPE versus CRYO differences remained statistically significant after correction for multiple comparisons. Adjusted p-values were 0.747 for the pre-trained instance model, 0.192 for the custom-trained instance model and 0.345 for the semantic model.
The semantic model achieved higher pixel overlap. The custom-trained instance model had lower boundary-distance error, measured by HD95, and higher panoptic quality (PQ), which reflects instance-level segmentation. Its PQ was 0.576 for FFPE and 0.613 for CRYO, compared with 0.560 and 0.550 for the semantic model. The semantic model nevertheless had better aggregated agreement across instance regions.
Table 5 compared Dice retention when training data fell from 80% to 20%. The instance model retained 95% for FFPE and 94% for CRYO; the semantic model retained 41% and 43%, respectively. The lowest training condition involved only 4 patients, making this a cohort-specific result rather than a general estimate of data efficiency.
The authors highlight a gap between Dice and PQ. Dice can remain high when adjacent nuclei are merged, whereas PQ captures missed, merged and split nuclei. Pixel overlap alone therefore cannot establish suitability for nuclear counting or lymphocyte density estimation. Task-specific detection and counting validation remains necessary.
#Interpretation
Here, comparable means that preparation-related differences were small, inconsistent in direction and not significant after adjustment. It does not establish interchangeability across laboratories or eliminate differences between tissue sections. The authors present CRYO as suitable for automated morphometric analysis rather than superior to FFPE.
The authors describe CRYO slides as ready within 2 to 3 hours, compared with multi-day FFPE processing. CRYO avoids formalin, but glyoxal is itself an irritant and sensitiser requiring appropriate handling.
Model choice should follow the downstream task. Foreground-region measurement may favour the semantic model, while counting individual nuclei may favour an instance-oriented approach. The instance model could miss faint or poorly focused nuclei, and its shape assumptions may limit performance on highly irregular or substantially overlapping nuclei.
#Limits and disclosures
The small cohort had limited representation of individual lymphoma subtypes, preventing reliable subtype-specific analysis. FFPE and CRYO sections came from different tissue fragments and were annotated independently. Patient-level pairing does not remove differences in tissue composition or annotation between sections.
All images came from a single institution using one microscope and camera system. Haematoxylin-only staining also limits extrapolation to other staining conditions. Performance across laboratories, imaging platforms and processing methods remains to be established.
The training-data comparison did not match model capacity: the semantic model was substantially larger. Its greater performance loss with less training data cannot establish an intrinsic data-efficiency advantage for the instance model. Larger independent cohorts and comparisons matched for model capacity are needed.
The authors declared no competing interests. Support came from academic and government research grants.
#Opinion
Pathologist's Brief considers this evidence a reason to evaluate rapid specimen preparation alongside the intended measurement task. A laboratory assessing nuclear counts should require counting validation and instance-level error review before relying on a favourable overlap score.
Frequently asked questions
Were these whole-slide images?
No, the researchers used microscope-camera fields rather than whole-slide scans. Both preparation groups were imaged at x40 after haematoxylin-only staining, using the same microscope and camera system. The results therefore need validation with other imaging platforms and staining conditions before they can be generalised to broader digital pathology workflows.
Does a higher Dice score mean more accurate nuclear counts?
No, Dice measures pixel overlap and can remain high when neighbouring nuclei merge. PQ assesses errors involving individual nuclei, including missed, merged and split objects. The authors therefore call for task-specific validation of nuclear detection and counting, alongside overlap and instance-level measures, before judging suitability for counting applications.
Did the reduced-data experiment establish which model needs less training data?
It showed relative sensitivity within this cohort, without establishing a general model advantage. The smallest training group contained only 4 patients, and the models differed substantially in capacity. The authors recommend larger independent cohorts and comparisons matched for model capacity to determine whether the observed difference generalises.