# Routine liquid-based cytology for a compact lung cancer gene panel: a small pilot with clear limits

> In a small single-centre pilot, residual liquid-based cytology material could be run on a compact lung cancer panel, with 95.7% concordance on 46 evaluable samples. The RNA module failed in six of 51 samples, so the supportable claim is feasibility with caveats.

Type: Briefing · Topic: Cytopathology
Published: 2026-11-29T10:01:07+00:00
Updated: 2026-11-29T10:01:07+00:00
Canonical URL: https://www.pathologistsbrief.com/article/lbc-lung-panel-pilot-feasibility
Publisher: Pathologist’s Brief
Source: https://doi.org/10.1002/cncy.70135
Author: Editor
Reviewer: Pathologist’s Brief editorial team
Review date: 2026-11-29

## Reporting

Can residual routine liquid-based cytology material go straight to a compact multigene sequencing panel for lung cancer that uses DNA and RNA, without special pre-analytical steps such as freezing a cell pellet or moving cells to a nucleic acid stabilisation tube? Authors in Japan examined this in a small, single-centre pilot feasibility study, reported by Shinomiya et al. in [Cancer Cytopathology, September 2026](https://doi.org/10.1002/cncy.70135).

The team collected 69 residual specimens between 2021 and 2024 at one centre. They were bronchial brush or forceps washings (15, 21.7%), needle washings (41, 59.4%) and pleural fluid (13, 18.8%). Of these, 36 (52.2%) were fixed with the first fixative and 33 (47.8%) with the second. Fixative use was not controlled prospectively. The paper says the two fixatives were used randomly across specimens, with fixation done by personnel blinded to clinical background, but no allocation procedure is given.

Nucleic acid quality was measured for both DNA and RNA, using a DNA integrity number and a DV200 value. The mean DNA integrity number was 6.2 ± 1.5 and the mean DV200 was 16.4 ± 12.1%. In plain terms, DNA integrity was generally well preserved, while RNA integrity was more variable.

The panel was run on 51 specimens from 50 cases that were cytologically positive and had an earlier clinical companion-diagnostic result. The DNA module worked in all 51. The RNA module failed in six of 51 (11.8%), and all six failures were in specimens in the second fixative.

Performance was assessed in 46 samples, after five RNA-failed samples with no DNA-module finding were excluded. Against the reference companion-diagnostic result, concordance was 95.7% (95% CI, 85.2 to 99.5). Sensitivity was 92.3% (24/26), specificity 100%, positive predictive value 100% and negative predictive value 90.9%.

In the cross-tabulation, 24 panel-positive samples were reference positive and none were reference negative. Of the panel-negative samples, two were reference positive and 20 were reference negative, giving 46 in total.

When the five excluded samples were counted in an intention-to-test analysis, sensitivity fell from 92.3% (24/26) to 88.9% (24/27). One of the five excluded samples was a clinically ALK fusion-positive case.

The two false negatives were one EGFR L858R and one MET exon 14 skipping alteration. Both were in pleural fluid specimens with marked inflammation and very few atypical cells. Across the full tested cohort of 51, the panel detected five of the seven RNA-dependent alterations (71.4%).

DNA integrity, DV200 and RNA yield were lower with the second fixative than with the first. Pleural fluid specimens gave more DNA and RNA yield but lower DV200, which the authors also found independently in multivariate regression.

RNA yield looked related to whether the RNA module succeeded. Among samples with RNA yield of 50 ng or more, 37 of 38 (97.4%) succeeded, and all 31 (100.0%) with 100 ng or more succeeded. DV200 was not consistently lower in the failures, though the numbers are small.

The authors concluded that panel testing remains feasible in routine liquid-based cytology specimens if cellularity and tumour-cell fraction are sufficient, that fixative choice matters, and that molecular testing should be triaged with attention to tumour-cell adequacy on the matching stained slide.

## Interpretation

The headline 95.7% is a per-protocol figure on 46 of 51 samples. The 92.3% sensitivity rests on only 26 reference-positive cases. The intention-to-test sensitivity of 88.9% and the 11.8% RNA failure rate are closer to what a laboratory would meet in practice. One RNA failure was a clinically ALK-positive case that the panel would have missed.

The abstract states that routine specimens can be applied without special pre-analytical processing. That wording is stronger than six failures in 51, all in one fixative, and one missed ALK case allow. This briefing therefore does not repeat it as a finding.

The reference specimens were often different from the panel specimens, with sampling sites and time points not necessarily the same. Disagreement with the reference therefore cannot be separated from tumour heterogeneity. The link between fixative and results is observational and was not controlled.

For laboratories in India and elsewhere, the practical message is general. A laboratory that sends residual liquid-based cytology material to a panel should audit fixative, cellularity, RNA yield and assay failure against its own cases. It should use the stained slide to judge tumour-cell adequacy before sending material. One pilot does not replace local validation.

## Opinion

This is a practical, clearly framed question, with transparent counts and an honest limitations paragraph. It is useful for laboratories thinking about workflow.

But it is a single-centre pilot with small numbers, a reference test on often different specimens, a per-protocol headline and failures concentrated in one fixative. "Feasible with caveats" is the supportable claim, and the abstract's wording runs ahead of the data.

Links between some authors and the panel's maker are declared: one author is an employee of the maker, and a senior author reports research funding from the same company.

## Limits

The study was done at a single centre. The numbers are small, with 26 reference-positive and 20 reference-negative evaluable samples. The headline figures exclude five RNA-failed samples. The reference specimens were often different from the panel specimens.

Cases were selected because earlier results existed, so patients with scant tissue may be under-represented. Fixative use was not controlled prospectively. No minimum tumour-cell threshold was defined, and the stage at which RNA degradation occurred was not determined.

The paper gives no clinical outcome or turnaround data and no multicentre validation. This briefing summarises one study, is not a validated protocol and gives no advice on patient management.

## Frequently asked questions

### Which specimens did the study use?
The study used residual liquid-based cytology material from one centre. It included bronchial brush or forceps washings, needle washings and pleural fluid, 69 specimens in all. Fifty-one specimens from 50 cytologically positive cases with an earlier companion-diagnostic result were run on the panel.

### How often did the RNA part of the panel fail?
The RNA module failed in six of 51 specimens (11.8%), and all six were in the second fixative. The DNA module worked in all 51. One RNA failure was a clinically ALK fusion-positive case, so the failures matter in practice.

### Does the study show routine cytology needs no special handling?
No, it shows feasibility with caveats. The pilot was small and single-centre, and failures clustered in one fixative. The authors themselves say fixative choice matters and that tumour-cell adequacy on the matching stained slide should guide triage. Local validation is still needed.