On this page
- What interpretable AI means and why it matters
- What the review covered
- Explanations built into the model
- Explanations added after the fact
- What heatmaps and attention maps can and cannot tell a reporting pathologist
- Open problems the authors list
- Using this knowledge in a laboratory
- Frequently asked questions
#What interpretable AI means and why it matters
When an AI tool highlights part of a slide, a reporting pathologist naturally asks why. Interpretable AI tries to answer that question. The aim is to show which parts of an image, which features or which concepts led a model to its output.
The terms interpretability, explainability, explainable AI and transparency are often used interchangeably. The authors of the review discussed here say the distinction between them remains subtle and unclear, and they do not separate them either. This article does the same.
The authors also describe a trade-off between how complex a model is and how interpretable it is. They suggest that explanations that are more biologically and clinically meaningful could match what pathologists need better than saliency maps alone.
#What the review covered
Wang et al., authors in the United States, published a review in Patterns, October 2026. It is a method-centric review of original research articles. The authors searched one bibliographic database, restricted the search to original research articles and found 373 papers.
They removed 97 papers. These were reviews, perspectives or dataset papers that the automatic filter missed, or papers that did not specifically focus on interpretable AI for pathology. After manual screening, that left 276 papers, from 2015 to 1 July 2026.
Of the 276 papers, 86.2% address primary tumours, meaning invasive cancer and precancerous lesions. A further 3.6% address cancer metastasis, and 10.2% cover other diseases such as inflammatory disease, infectious disease and Alzheimer's disease. The papers were also grouped into five task themes: diagnosis, prognosis, tissue and cellular analysis, molecular and genetic profiling, and other tasks.
The review reports no pooled performance data and does not compare methods on a benchmark. The authors also say that the categories in their taxonomy are not strictly mutually exclusive, so a single paper can fit more than one.
#Explanations built into the model
The taxonomy has two branches. The first is interpretable-by-design models, where the architecture or algorithm is inherently interpretable. The review describes four principles.
Classical machine learning on human-interpretable features. Measured features such as nuclei, glands, cell density or the spatial arrangement of lymphocytes are fed to simple models. A pathologist can inspect the inputs directly.
Attention mechanisms. The model learns a weighted average, and the weights indicate which parts of the input matter most. They are usually shown as a saliency map. In multiple instance learning, a slide is divided into patches, and the weights point to the patches that drive the slide-level prediction. In this review, 105 papers (38.0%) used an attention mechanism.
Prototype-based models. These use case-based reasoning of the form "this looks like that". A decision rests on similarity to prototypes seen during training.
Prior-knowledge-guided models. Clinical guidelines or biological hypotheses are built into the design. Examples include models that first predict intermediate clinical attributes, or that grade components separately before combining them.
The authors say a drawback of by-design methods can be compromised predictive power.
#Explanations added after the fact
The second branch is post hoc techniques. These explain an already trained, usually opaque model without altering its predictions. The authors say that inferring predictive mechanisms from post hoc explanations alone is more limited.
The review groups post hoc work into two types.
Attribution methods ask where in the input the model is focused. The review describes gradient-based, perturbation-based, decomposition-based and surrogate-based families.
Latent-space analysis looks at what the model has learned internally. Examples include clustering learned features and linking neurons or directions to human-understandable concepts such as cell types or tissue patterns.
The authors also describe an emerging trend toward concept-based explanations. These use human-interpretable units such as visual patterns, cellular structures or decision rules.
#What heatmaps and attention maps can and cannot tell a reporting pathologist
The two main kinds of map differ in sharpness. Attention assigns a weight to each patch, so its saliency map has a much lower resolution than the input. Post hoc attribution methods are designed for standard-size images and give maps with the same or similar resolution as the input.
The authors say the two can complement each other. Attention can locate important patches, and attribution can then highlight finer structures such as individual cells or pixels.
Evaluating explanations is hard because the ground truth is often unknown. There is no universally used protocol. Evaluations typically look at four things: faithfulness (how well the explanation reflects true model behaviour), robustness (how stable it is when the input is perturbed), simplicity, and human-grounded evaluation (alignment with expert knowledge).
In the surveyed papers, qualitative evaluation dominates. It typically shows that highlighted areas match the regions pathologists consider relevant. A smaller subset of studies is quantitative. The authors say the judgement and validation process is typically subjective and hard to reproduce, so the conclusions are often weak.
Almost all evaluations were run on the same cohort used to develop the model. It therefore remains unclear whether the explanations encode dataset-specific biases, or whether they generalise to differences in scanning hardware, staining protocols and patient populations. Only a few studies probe this.
User studies exist. In one example, junior pathologists diagnosing gastritis improved in speed and accuracy when saliency maps were available. The authors say such human-centred evaluations remain highly heterogeneous and largely incomparable across studies.
The authors also describe documented criticism of attention and gradient-based methods for faithfulness, robustness and stability. Attention may carry interpretability value, but it should not be over-interpreted as faithful evidence of model reasoning. Small input changes can change gradient-based explanations, and some gradient-based methods give unchanged explanations even when model parameters are randomised.
These methods remain valuable for generating hypotheses and auxiliary insight. The authors conclude that explanation outputs should be interpreted as hypotheses rather than definite conclusions about model reasoning, with particular caution in healthcare.
The review adds a regulatory point. The medical device regulator in the United States does not mandate interpretability. It treats model opacity as a risk to document and mitigate, and it warns that saliency maps and feature-importance visualisations may detract from a user's understanding unless they are rigorously validated for their intended users.
#Open problems the authors list
The authors call the field fast-growing but immature. The problems they list include:
- No rigorous, agreed definition of interpretability.
- No standardised evaluation protocols.
- No standardised benchmark datasets with interpretability-specific ground truth, and no agreed metrics, especially for concept-based explanations.
- The most widely used methods may not be the most faithful.
- Practices that diverge from the core idea, such as treating generic feature selection as interpretable AI, or treating a display of the highest and lowest scoring samples as an explanation without further analysis.
The authors want standardised definitions, benchmarks and evaluation protocols. They also want human-centred, utility-based evaluation, which tests whether an explanation helps or hinders a user's decision in a real clinical workflow.
They state that their review gives less weight to clinical deployment and does not systematically cover software or implementation.
#Using this knowledge in a laboratory
The review does not give laboratory instructions, but several general points follow from it. They apply to laboratories in India and elsewhere.
- Treat a highlighted region as a hypothesis to check against the slide, not as proof of the model's reasoning.
- Ask whether the explanation was tested on cases from other scanners, stains and centres.
- Ask whether pathologists were involved in judging the explanation.
- Remember that an explanation does not replace performance validation on local slides.
Any local adoption would need local validation on local scanners, stains and case mix. The review gives no evidence on turnaround, workload or patient outcomes, so none of these can be assumed from it.
Frequently asked questions
Can a heatmap show how an AI model reached its result?
Not reliably, according to the review authors. Heatmaps and attention maps should be read as hypotheses, not definite conclusions about model reasoning. Attention and gradient-based methods have documented problems with faithfulness, robustness and stability, so a highlighted region needs checking against the slide.
What is the difference between built-in and post hoc explanations?
Built-in explanations come from a model designed to be interpretable, while post hoc explanations are added to an already trained model. Post hoc methods do not alter its predictions. The authors say by-design methods can lose predictive power, and post hoc explanations alone are more limited for inferring mechanisms.
How were explanations in these papers usually evaluated?
Mostly qualitatively, by checking that highlighted areas match regions pathologists consider relevant. A smaller subset of studies was quantitative. Almost all evaluations used the same cohort as model development, so it is unclear whether explanations hold across scanners, stains and patient populations. Only a few studies probe this.
Source
https://doi.org/10.1016/j.patter.2026.101664 ↗For education and professional reference. This does not give patient-specific advice or replace professional judgement, local protocols or consultation. Editorial standards.




