Pathologist’s Brief

H&E prediction of gastric biomarkers: external results and limits of pre-screening

Quick answer

H&E-based prediction showed potentially useful discrimination for MSI/dMMR and EBV, but evidence for all five gastric biomarkers remains insufficient for clinical triage or replacement of confirmatory testing.

Black-and-white photo of gastric histology slides beside a monitor showing confidence-interval plots and tissue images.
AI-generated illustration, Pathologist’s Brief
On this page
  1. Why predict biomarkers from H&E?
  2. How the review separated the evidence
  3. Results by biomarker
  4. Bias and certainty
  5. Limits and disclosures
  6. What this means for laboratories
  7. Frequently asked questions

#Why predict biomarkers from H&E?

Lee et al., in Front. Oncol., 9 September 2026, reviewed deep learning prediction of biomarkers in gastric and gastro-oesophageal junction adenocarcinoma. The article states that it has been corrected.

MSI/dMMR, HER2, PD-L1 and CLDN18.2 can inform systemic-treatment selection. EBV identifies a biologically and prognostically relevant molecular subtype, but is not an established stand-alone treatment-selection biomarker comparable with the other markers. This distinction matters when discussing a shared image-based screening approach.

Molecular assays, immunohistochemistry (IHC) and in situ hybridisation consume tissue, incur costs and are not universally available. Routine haematoxylin and eosin (H&E) slides are already available from biopsied or resected tumours, making inexpensive image-based pre-screening attractive in principle.

H&E models learn tissue patterns associated with genotype, cell state and the microenvironment. They do not directly measure the biomarker molecule. Heatmaps and morphological associations show correlation rather than a marker-specific causal mechanism.

#How the review separated the evidence

The researchers searched PubMed, Embase, Cochrane and Web of Science through 8 August 2026. Independent reviewers selected studies and re-extracted performance from full reports and supplementary material. Formal synthesis required peer-reviewed full texts with H&E image inputs and molecular, IHC or in situ hybridisation reference standards.

There were 28 included studies: 18 addressed MSI/dMMR, 14 EBV, 2 HER2, 2 PD-L1 and 1 CLDN18.2. Marker groups overlapped, so these counts are not separate sets of studies. Cohorts were mainly retrospective.

The review distinguished genuinely external, patient-level evaluations with clinically anchored reference standards and no test-cohort adaptation from internal held-out evaluations. Results influenced by test-set model selection, uncertain reference standards or reused cohorts were retained as secondary or sensitivity evidence.

No marker had enough independent estimates from a common clinical setting to support statistical pooling. Differences in specimens, analysis units, reference standards and validation, alongside repeated cohort and model use, prevented a stable summary estimate. Neither pooled accuracy nor formal between-study inconsistency estimates were reported.

#Results by biomarker

AUROC is the area under the receiver operating characteristic curve. The following external-independent results are individual estimates, not pooled performance.

MSI/dMMR: The eligible external-independent AUROC was 0.767, with a 95% confidence interval of 0.726 to 0.830. An external estimate of 0.874 was retained only in a reference-standard sensitivity analysis because the institutional assay was not reported. A separate patient-disjoint internal held-out evaluation reported sensitivity 0.833 and specificity 0.885 at a training-selected threshold; it was not external-independent evidence.

EBV: External-independent AUROCs were 0.941, with a 95% confidence interval of 0.920 to 0.970, and 0.859, with an interval of 0.823 to 0.919. An external multicentre evaluation using a development-set threshold reported sensitivity 0.969 and specificity 0.759. A separate biopsy study reported external AUROC 0.870, but its external cohort informed model selection, making that result secondary evidence.

HER2: Neither study supplied an AUROC with valid sampling uncertainty for the main evidence displays. An external evaluation reported sensitivity 0.857 and specificity 0.901, but external data had informed component or model selection. The result therefore remained test-influenced secondary evidence, rather than an independent validation of a fixed test.

PD-L1: Neither study provided an external-independent, patient-level evaluation with recoverable diagnostic counts. Reference definitions differed. This is sparse, hypothesis-generating evidence and does not establish that prediction is ineffective.

CLDN18.2: The external cohort of 98 yielded AUROC 0.856, with a 95% confidence interval of 0.775 to 0.926. At a tuning-cohort threshold selected to target 90% sensitivity, external sensitivity was 1.000 and specificity 0.452. Their respective confidence intervals were 0.863 to 1.000 and 0.335 to 0.573. These results came from a single industry-funded study and do not establish generalisability or clinical utility.

#Bias and certainty

Across 42 analytic scopes, QUADAS-2 judged 40 at high risk of bias and 2 unclear. PROBAST judged all 42 high risk. Concerns included sampling, small event counts, unclear patient separation, test-set threshold or model selection, uncertain reference labels and possible overlap between pretraining and evaluation data.

GRADE certainty was very low for MSI/dMMR, EBV, HER2 and PD-L1, and low for CLDN18.2. Serious risk of bias and imprecision limited CLDN18.2; the other markers also had indirectness and/or imprecision alongside very serious bias concerns. No included study evaluated final-model calibration or reported a reproducible advance sample-size calculation.

AUROC alone cannot specify how many biomarker-positive tumours a triage threshold would miss, how many confirmatory tests it would avoid or what predictive values a laboratory would obtain.

#Limits and disclosures

The hierarchy used to select and classify estimates was finalised during full-text re-extraction rather than prespecified in the protocol, although it used design and dependence rather than performance magnitude. Restriction to peer-reviewed full texts may have missed emerging, null or unfavourable findings. Some participant, report and pretraining overlap could not be fully quantified.

Sparse independent evidence prevented subgroup analyses, meta-regression and formal assessment of inconsistency or publication bias. Failure to assess publication bias does not establish its absence. CLDN18.2 entered through a protocol amendment after peer review and was represented by a single eligible study. Some planned database searches were not performed because access was unavailable, and stand-alone preprint searches could not be documented.

The review received public research and health research funding in South Korea. The funders had no role in design, data collection and analysis, publication decisions or manuscript preparation. The authors declared no commercial or financial relationships that could be construed as competing interests.

#What this means for laboratories

The evidence does not support replacing IHC, in situ hybridisation or molecular testing with H&E prediction. Even a pre-screening or rule-out role remains unestablished, despite useful discrimination in selected evaluations.

The authors call for a predefined clinical role, a fixed model and operating threshold, calibration assessment and patient-level external validation across institutions before prospective evaluation of clinical utility and false-negative safeguards. Gastric and gastro-oesophageal junction validation should include biopsies when pre-treatment triage is intended and should address staining, scanning and institutional differences. Performance in another organ cannot validate a gastric biomarker test.

Frequently asked questions

Is EBV being assessed as the same kind of biomarker as HER2?

No, the review treats EBV as a biologically and prognostically relevant molecular subtype. It does not describe EBV as an established stand-alone treatment-selection biomarker comparable with HER2 or the other markers. Combining their image-prediction evidence therefore requires keeping the different clinical meanings of the targets explicit.

Why were the reported accuracy results not pooled?

There were too few independent estimates within comparable clinical settings. Reports reused cohorts, models and thresholds, while specimens, analysis units and reference standards differed. Some external datasets also influenced model selection. Pooling these results would have treated dependent or differently validated evaluations as though they measured a common independent test.

Does a high AUROC tell a laboratory how many positive tumours will be missed?

No, AUROC alone does not establish the false-negative rate at a chosen threshold. The intended operating rule needs separate evaluation, alongside calibration and predictive values. The review found no final-model calibration assessments, leaving the safety and practical value of a proposed pre-screening workflow unestablished in the intended laboratory population.

Source

https://doi.org/10.3389/fonc.2026.1953562 ↗

For education and professional reference. This does not give patient-specific advice or replace professional judgement, local protocols or consultation. Editorial standards.