# Testing H&E foundation models on stimulated Raman histology of lung tumours

> H&E-trained foundation models showed no statistically significant advantage over a general-purpose image network in classifying lung tumours on stimulated Raman histology. The authors judged performance too low for clinical use.

Type: Briefing · Topic: Digital pathology
Published: 2026-11-23T10:15:28+00:00
Updated: 2026-11-23T10:15:28+00:00
Canonical URL: https://www.pathologistsbrief.com/article/foundation-models-raman-histology-lung
Publisher: Pathologist’s Brief
Source: https://doi.org/10.7150/jca.135384
Author: Editor
Reviewer: Pathologist’s Brief editorial team
Review date: 2026-11-23

## Reporting

Schröder et al., authors in Germany, tested whether models trained on conventional slides could distinguish lung tumour types on stimulated Raman histology. This label-free laser imaging method produces H&E-like images from fresh tissue without processing or staining. [Journal of Cancer, September 2026](https://doi.org/10.7150/jca.135384)

The study included 93 patients at one centre. Of these, 68 had non-small cell lung cancer (37 squamous cell carcinomas and 31 adenocarcinomas) and 25 had pulmonary metastases. The authors took 250x250 pixel tumour patches from the images and split the data by patient, with 70% for training and 30% for testing.

The team compared eleven pathology foundation models trained on H&E slides, with a general-purpose image network pretrained on everyday photographs as the reference. The models stayed frozen while the team trained simple classifiers on their embeddings, the numerical features extracted from each patch. The tasks were to distinguish non-small cell lung cancer from pulmonary metastases and adenocarcinoma from squamous cell carcinoma.

Linear probing used logistic regression and non-linear probing used a small two-layer network. The authors assessed balanced accuracy (BA), area under the receiver operating characteristic curve (AUROC) and a correlation measure abbreviated MCC. The results below are at patient level.

For the linear probe on non-small cell lung cancer versus metastasis, reference network BA was 0.64 ± 0.04 and AUROC was 0.82 ± 0.03. The highest foundation model scores were BA 0.73 ± 0.04 and AUROC 0.87 ± 0.06.

For the linear probe on adenocarcinoma versus squamous cell carcinoma, reference network BA was 0.52 ± 0.08 and AUROC was 0.55 ± 0.06. The highest foundation model scores were BA 0.69 ± 0.07 and AUROC 0.75 ± 0.04. Each linear result is a mean with a standard deviation across 10 folds.

For non-linear probing of non-small cell lung cancer versus metastasis, reference network AUROC was 0.82 (95% CI 0.63 to 0.96) and the highest foundation model AUROC was 0.93 (95% CI 0.80 to 1.00). The authors found no statistically significant difference from the reference network in any comparison.

## Interpretation

It is tempting to assume that features learned on H&E slides will transfer across stains or imaging methods. In this study, the comparisons could not distinguish foundation model performance from that of the general-purpose reference network. For laboratories evaluating a new imaging method or stain, the result illustrates the value of including a simple reference network when testing transfer.

## Opinion

This was a modest exploratory study. The evidence supports a narrow conclusion about the lack of a demonstrated advantage in these comparisons. It leaves open whether foundation models could work with this imaging method, including the possibility the authors raise of building a model specifically for stimulated Raman histology.

## Limits

The small cohort from one centre limited statistical power, and the metastases came from a range of primary sites. Two adenocarcinomas and one squamous cell carcinoma from contralateral lung cancers were counted as metastases, and the paper does not say how second primaries were excluded. The non-linear confidence intervals were wide. The highest scores were the best of eleven models on the same test data, so they are likely optimistic. The supplementary tables were not reviewed.

The paper goes beyond its findings when it says the foundation models could not encode a signal that distinguishes non-small cell lung cancer from metastasis. The reference network already showed separation, with an AUROC of 0.82, and the foundation model AUROC of 0.93 in the non-linear test conflicts with the statement in the limitations that an AUC above 0.90 was infeasible.

The authors cite frozen-section accuracy of 83.3% to 99.4% and a benchmark of no more than 20 minutes from tissue removal to communication of the diagnosis. Stimulated Raman histology scanning alone took up to 22.8 minutes, beyond that benchmark. These timings give limited support for intraoperative use.

## Frequently asked questions

### Did the researchers retrain the foundation models on Raman images?
The foundation models were kept frozen. They turned each tumour patch into a set of numerical features called an embedding. The researchers trained logistic regression and a small two-layer network on those embeddings to see whether the features could distinguish the tumour categories.

### What does the ± sign mean in the linear results?
It gives the standard deviation across 10 folds. Each fold trained a separate probe, and all were scored on the same test set. The spread therefore reflects variation between trained probes. It does not show how much the scores might change with a different group of patients.

### How did scanning time compare with the frozen-section benchmark?
The longest reported scan exceeded the frozen-section benchmark cited in the paper. That benchmark covers the time from tissue removal to communication of the diagnosis. The stimulated Raman histology time covers scanning alone, which limits what the study can establish about use during surgery.