# Digital and AI pathology from biobank to companion diagnostic: a practical map

> Using digital and AI pathology in practice depends on governed tissue, linked laboratory systems, validated workflows and appropriate regulatory routes. A narrative review maps this infrastructure across drug development.

Type: Reference · Topic: Digital pathology
Published: 2026-11-11T05:07:08+00:00
Updated: 2026-11-11T05:07:08+00:00
Canonical URL: https://www.pathologistsbrief.com/article/digital-ai-pathology-practical-map
Publisher: Pathologist’s Brief
Source: https://doi.org/10.1136/bmjonc-2026-001208
Author: Editor
Reviewer: Pathologist’s Brief editorial team
Review date: 2026-11-11

## What this review covers

Zhu et al. examine the infrastructure connecting pathology models to research workflows and patients in [BMJ Oncology, 27 October 2026](https://doi.org/10.1136/bmjonc-2026-001208). This structured narrative review searched literature and regulatory documents from January 2019 to April 2026 and retained 78 sources.

It is an illustrative, authority-weighted synthesis, not an exhaustive systematic review. No protocol was registered, and source selection retained some subjectivity. Its focus is the operational and regulatory connections across drug development, not a comparison of algorithm architectures.

## Where digital pathology sits in the drug development pipeline

- **AI-ready biobanks:** link tissue, images and clinical information through standardised collection, processing, annotation and governance.
- **Preclinical pathology:** support quantitative tissue assessment and toxicology within the relevant laboratory practice framework.
- **Patient screening:** use tissue biomarkers and AI-assisted assessment to support trial stratification and eligibility workflows.
- **Trial endpoints:** support reproducible measurement and adjudication, with traceable analysis and validation appropriate to the intended use.
- **Central pathology review:** organise consistent review across participating sites, with controlled image access and documented decisions.
- **Companion diagnostics:** connect a validated test to selection for a particular therapy, serious adverse-effect risk or response monitoring.

The review treats these as connected stages. A promising model still depends on reliable specimens, data provenance and a validated route into the workflow where its output will be used.

## The laboratory infrastructure behind it

Laboratory information systems manage specimen and patient information. Image management systems organise whole-slide images and their links to laboratory records. AI orchestration connects these records and images to analysis tools, while structured reporting returns results in a usable, traceable form.

The review stresses image version tracking, analysis parameters, records of user modifications and version-locking of tools contributing to clinical decisions. It describes integration as letting images and data reach the analysis workflow directly, rather than relying on disconnected research processes.

The review describes quality assurance as extending beyond algorithm accuracy:

- Validation of the digital workflow against its intended clinical use, with revalidation after significant system changes.
- Checks of focus, colour fidelity and completeness of tissue capture, with defined routes for rescanning failed images.
- Detection of artefacts such as folds, pen marks, bubbles and missing tissue before interpretation or AI analysis.
- Monitoring of scan failures, rescan rates and changes in AI output distributions, and audit of AI-assisted cases.

## Regulatory routes described

The review describes US Food and Drug Administration (FDA) routes according to intended use. These terms carry different meanings:

- **510(k) clearance:** marketing authorisation based on substantial equivalence to a legally marketed predicate.
- **De Novo authorisation:** a route for a novel device of low to moderate risk without a valid predicate, establishing a new classification.
- **Premarket approval (PMA):** the more stringent route for high-risk Class III devices, requiring evidence of safety and effectiveness.
- **Breakthrough Device designation:** expedited development and review status, not marketing authorisation.

Whole-slide imaging systems intended for primary diagnosis are described as Class II devices subject to special controls. Image management software used only for acquisition, storage, transmission and display may be exempt as Class I. Diagnostic interpretation, quantitative analysis, AI classification or analysis affecting trial inclusion or outcomes can bring software under Software as a Medical Device regulation.

For AI-enabled software, the review discusses risk-based credibility and the Predetermined Change Control Plan. Such a plan describes proposed modifications, the modification protocol and impact assessment for controlled post-market updates.

Companion diagnostics are described as Class III devices generally requiring PMA. Co-approval with the relevant drug or device is encouraged when the test is essential to determine clinical benefit.

Outside the US, the review describes the EU AI Act as adding high-risk obligations for medical-device AI alongside the EU Medical Device Regulation. The International Medical Device Regulators Forum provides shared risk terminology for software, but does not remove differences between jurisdictions.

## Recurring problems

- **Generalisability:** changes in stain, scanner, institution and patient mix can reduce accuracy. Normalisation, augmentation and pretraining mitigate domain shift without eliminating it.
- **Ground truth and annotation:** specialist annotation remains demanding, and disagreement between pathologists limits what a model can learn reliably.
- **Bias:** under-represented demographic groups, image acquisition systems and clinical contexts may see poorer performance, so subgroup results need explicit reporting.
- **Validation and reporting:** internal cross-validation alone is insufficient for deployment. The review calls for prospective external evaluation, multi-site evidence and applicable reporting frameworks, including TRIPOD-AI, CLAIM, DECIDE-AI and STARD-AI.
- **Interpretability:** attention maps show where a model attended, but do not establish why a feature is causally informative.
- **Data governance:** consent provenance, de-identification, privacy, security and cross-border agreements require work throughout multi-site projects.
- **Cost and reimbursement:** scanners, storage, networks, integration and technical support create continuing costs. Real-world cost-effectiveness and reimbursement remain barriers.
- **Adoption:** routine workflow integration lags academic development and varies between academic, community and contract research settings.
- **Professional responsibility:** labour effects, consent for archival specimen use, equitable access and accountability for incorrect recommendations require governance. The review supports assistive use rather than autonomous replacement of pathologists.

## How to use this page

Use this map to locate infrastructure and evidence questions in the full review. It summarises a narrative review written largely from a US regulatory perspective and is not regulatory advice. Consult the full review, current regulations and accreditation requirements; Indian readers should check local requirements.

Several authors are affiliated with a company that develops one of the integrated pathology platforms compared in the review; the authors state that it was assessed on the same publicly verifiable criteria as the other platforms. One author is affiliated with a contract research organisation, which the authors state did not fund or influence the review. The authors report no specific grant for this work.

## Frequently asked questions

### Is an attention heatmap an explanation of biological mechanism?
No. An attention heatmap shows where a model focused, not why a feature is causally informative. The review distinguishes visual interpretability from evidence of mechanism. It describes strong external validation or mechanistic plausibility as relevant to regulatory confidence, alongside the wider evidence needed for a particular use.

### Does regulatory status depend on what image software does?
Yes, intended use affects the regulatory route described in the review. Software limited to image storage and display is treated differently from software performing diagnostic interpretation or analysis that influences trial eligibility or outcomes. Regulatory terms also differ, so an expedited-review designation should not be confused with marketing authorisation.

### What needs monitoring after a digital workflow goes live?
The review calls for continuing monitoring of image quality and AI performance. This includes scan failures, rescanning, changes in output distributions and audits of AI-assisted cases. Revalidation after significant changes to the system helps connect initial validation to the actual workflow used in routine practice over time.