# Deep learning for colorectal cancer detection on whole-slide images

> Deep learning showed high pooled sensitivity for colorectal cancer detection on whole-slide images, but specificity varied. Most primary cohorts came from one study, limiting confidence in how well the results apply to other laboratories.

Type: Article · Topic: Digital pathology
Published: 2026-11-18T10:16:15+00:00
Updated: 2026-11-18T10:16:15+00:00
Canonical URL: https://www.pathologistsbrief.com/article/colorectal-cancer-deep-learning-detection
Publisher: Pathologist’s Brief
Source: https://doi.org/10.3389/fonc.2026.1885546
Author: Editor
Reviewer: Pathologist’s Brief editorial team
Review date: 2026-11-18

## Why slide-level and patient-level counts matter

Yong et al., researchers in China, reviewed diagnostic accuracy in [Frontiers in Oncology, 17 August 2026](https://doi.org/10.3389/fonc.2026.1885546). Studies had to report true positives, false positives, false negatives and true negatives at slide or patient level, or provide enough information to reconstruct those counts unambiguously. Patch-level and area-under-the-curve (AUC) results alone did not qualify.

The authors note that patch-level results cannot be assumed to translate into slide-level or patient-level performance. AUC describes discrimination across thresholds. At the threshold used in practice, specificity determines how often slides or patients without the target condition are flagged for review.

## What the review included

The researchers searched five bibliographic databases up to 10 May 2026. They found 4,687 records and screened 2,307 records classed as unique by their deduplication procedure. A later audit found some residual duplicates, which did not affect the included studies.

Of the 8 studies included, 3 met the strict criteria for the primary analysis. They contributed 14 cohorts, of which 13 were patient-level, 1 was slide-level and 11 were external. The other 5 studies contributed seven cohorts with related endpoints, such as cancer grouped with high-grade dysplasia. These were used only in expanded and sensitivity analyses.

The reviewers used a standard risk-of-bias tool and also considered data leakage and the applicability of external validation.

## What the pooled numbers show

The primary cohorts recorded 5,402 true positives, 439 false positives, 68 false negatives and 3,596 true negatives. The modelled sensitivity was 0.982 (95% confidence interval 0.976 to 0.986), specificity was 0.959 (95% confidence interval 0.922 to 0.979) and AUC was 0.979.

The authors describe these estimates as exploratory. The analysis treated cohorts as independent, although one source study contributed 12 of the 14 primary cohorts. If cohorts from that study were correlated, the confidence intervals may be too narrow.

Crude specificity, calculated from summed counts, was 0.891 compared with the modelled 0.959. In the external cohorts alone, crude specificity was 0.780 and modelled specificity was 0.947.

## Why specificity varied

Specificity varied with the definition of a positive result, the unit of analysis and the influence of large true-negative denominators on the crude estimate. The only external slide-level cohort in the strict analysis had a specificity of 68.3%. The authors interpret this as a measure of false-positive slide calls and the review workload they can create. It does not establish how often patients were misclassified.

When the dominant study was removed from the strict analysis, crude specificity fell to 0.716 and modelled specificity was 0.851, with a wide interval of 0.447 to 0.976. The authors treated that model fit as unstable.

Sensitivity was high in most analyses, with some lower results. In the expanded set without the dominant study, modelled sensitivity was 0.942. One study in the expanded set reported 77.4% sensitivity for a broader endpoint.

## What it means for practice

The authors see a role for deep learning alongside pathologist review in prescreening, triage, workload prioritisation and quality control. The evidence falls short of the independent replication across multiple studies needed to support standalone diagnosis.

Local validation should report the diagnostic counts at both slide and patient level at the intended threshold. The authors also recommend measuring how many additional slides or regions require review, since accuracy estimates alone do not establish the effect on workload.

## Limits

The primary synthesis drew on a small and uneven set of studies and combined slide-level and patient-level results. Some 2 x 2 tables had to be reconstructed. Estimates of variation between cohorts were unstable, and most systems studied used convolutional networks.

The review was not prospectively registered. Some methodological choices, including how to classify borderline endpoints and when to accept reconstructed counts, evolved during full-text review. The review received public research funding, and the authors declared no conflicts of interest.

## Frequently asked questions

### Why can a high AUC still leave a laboratory with many slides to review?
A high AUC describes discrimination across thresholds and does not give the false-positive workload at the threshold a laboratory uses. The operating threshold determines which slides are flagged. Specificity at that threshold helps a laboratory judge how often slides without the target condition will need additional review.

### Can I apply the pooled specificity to my slide queue?
The pooled specificity does not directly estimate the false-positive rate for a local slide queue. The primary analysis mostly used patient-level cohorts, and slide-level calls have a different meaning for workload. Counts from local validation at the intended threshold can show how many slides without the target condition are flagged.

### Why were studies that grouped cancer with high-grade dysplasia analysed separately?
Grouping cancer with high-grade dysplasia changes which findings qualify as a positive result. The review kept those broader endpoints outside the strict primary analysis so they would not shape its cancer detection estimates. It used them in expanded and sensitivity analyses to examine how related endpoints affected the findings.