Quick answer

AI evidence in bone marrow examination is strongest for individual modalities. Lee’s narrative review found no prospectively validated comprehensive system combining morphology, raw flow, molecular or cytogenetic data and clinical information.

Black-and-white photo of a marrow slide beside a microscope and monitor displaying cell images and flow plots.
AI-generated illustration, Pathologist’s Brief
On this page
  1. Scope and diagnostic context
  2. What the evidence categories mean
  3. Why comprehensive integration remains unrealised
  4. Interpretation, regulation and governance
  5. Staged validation proposed in the review
  6. Review limitations and disclosures
  7. Questions to ask before using an AI tool in marrow reporting
  8. How to use this page
  9. Frequently asked questions

#Scope and diagnostic context

This reference page summarises Lee’s single-author narrative review in Blood Research, 16 October 2026. It is a review of published evidence, not a guideline.

Bone marrow interpretation combines peripheral blood, aspirate cytomorphology, trephine histology and immunohistochemistry with flow cytometry, cytogenetics and molecular genetics. The specimens contribute different information: aspirates resolve individual cells, while trephines preserve cellularity, fibrosis, focal infiltrates and spatial architecture. WHO-HAEM5 and the International Consensus Classification (ICC 2022) define entities through integrated criteria, so isolated image classification addresses only part of the diagnostic task.

#What the evidence categories mean

#Mature single-modality tools

These systems consume a single measured modality. The strongest evidence concerns aspirate cytology, trephine image analysis and flow cytometry, with performance approaching expert assessment for selected tasks. High overall accuracy can conceal errors in diagnostically important cell classes: a reviewed cytology system reported 99.0% overall accuracy but 81.0% average sensitivity.

The review describes the first all-digital bone marrow aspirate application authorised by the US FDA through the De Novo route. Its role is assistive, with operator verification required. It does not provide autonomous integrated marrow diagnosis. Automated cytogenetic systems reviewed were largely validated on non-neoplastic metaphases, leaving performance on complex neoplastic marrow karyotypes largely untested.

#Cross-modal prediction

These models estimate a label from another modality without ingesting that measured modality during use. Predicting NPM1 status from smear images is therefore cross-modal prediction, even when the reference label came from molecular testing. A reviewed image-only study reported an AUROC of 0.92 for NPM1 prediction, while another reported approximately 0.70, illustrating uneven genetic signal and different study settings. These estimates are not directly comparable and do not establish molecular testing replacement.

#Genuine multimodal fusion

Fusion jointly consumes multiple measured modalities at inference. Partial-fusion marrow studies exist, but comparisons with the strongest single-modality model are sparse and depend on the endpoint. Some endpoints improved; others did not consistently do so. Absence of consistent superiority does not establish absence of benefit.

The review found no peer-reviewed, prospectively validated comprehensive marrow system jointly using matched morphology, raw flow cytometry, cytogenetic or molecular outputs and structured clinical metadata to produce a unified WHO-HAEM5/ICC-aligned recommendation. Multimodal pre-training followed by image-only use does not meet this definition.

#Why comprehensive integration remains unrealised

Large paired, multi-institutional case datasets are missing. Public resources mainly support isolated modalities rather than morphology, raw flow, molecular data and longitudinal outcomes from the same patients. The required inputs also arrive at different times and may be incomplete, including dry taps, absent genetics and incomplete flow panels. Systems need explicit missing-data handling and outputs that remain interpretable when inputs are absent.

Generalisation is vulnerable to smear preparation, staining, section thickness, scanner optics, compression and cytometer variation. Batch effects can be learned as if they were biology. In a deployed flow classifier, real-world sensitivity was 69.0% versus 77.0% in validation; equipment-related signal changes also affected performance.

Rare cells and diseases are underrepresented, annotation is costly and expert labels vary. Divergent classification schemes and staining conventions complicate harmonised nomenclature. Technically difficult specimens, including dry-tap imprints and particle clots, are also underrepresented in training data.

#Interpretation, regulation and governance

Complex models can obscure the features driving their outputs. The review favours calibrated uncertainty, the ability to abstain and human-confirmed assistive use. Regulatory approaches to changing algorithms are still developing, while costly computation and energy requirements can restrict access in resource-limited centres.

Whole-slide images may contain identifying artefacts; flow files, variant calls and longitudinal records add governance demands. Controlled access and privacy-preserving collaboration may be more realistic than unrestricted sharing. Medico-legal responsibility remains unresolved when overconfident outputs occur in scant material, fibrosis, treatment effects or unusual genotype and phenotype combinations.

#Staged validation proposed in the review

Table 2 starts with multicentre retrospective external validation using frozen algorithms and temporal holdout. A silent prospective phase then runs the model in real time without affecting care, recording calibration, failures and disagreement with final sign-out.

Clinical-impact evaluation should assess time to actionable results, diagnostic concordance, re-review burden and safety events. Post-deployment surveillance should monitor drift, false reassurance, version changes and revalidation triggers. The reference standard should be case-level multidisciplinary consensus after routine modalities are available, with subgroup analysis and permission for the model to abstain. The review reports no published marrow AI clinical-impact trial.

#Review limitations and disclosures

This was a non-systematic review by a single author, without independent duplicate study selection or formal risk-of-bias assessment. Selection and confirmation biases are possible. Differences in tasks, comparators and validation designs limit cross-study comparisons; the study table is illustrative rather than exhaustive. Conclusions depend on evidence available during manuscript preparation.

Lee was an assistant editor of the journal and founded a company whose interest the author states is unrelated to the manuscript. Funding included government research grants and institutional research support.

#Questions to ask before using an AI tool in marrow reporting

  • Which measured inputs are available during actual use, and is the claim single-modality assistance, cross-modal prediction or fusion?
  • Does validation cover local preparation, staining, acquisition, flow panels, specimen quality and patient mix?
  • Were external and temporal cohorts separated, with case-level integrated reference standards?
  • How are missing modalities, rare classes, uncertainty and abstention handled?
  • Who verifies outputs, records overrides and monitors drift or version changes?
  • What governance controls apply to images, flow files, molecular results and secondary data use?

#How to use this page

Use this page to classify a tool’s intended task and to identify the evidence worth examining with haematopathologists and laboratory physicians. Read reported accuracy alongside class-specific errors, deployment inputs and validation design. The review supports local validation and operator-confirmed assistance; it does not establish a comprehensive autonomous marrow reporting system.

Frequently asked questions

Is predicting a mutation from a smear multimodal fusion?

No, predicting a mutation from a smear alone is cross-modal prediction. The distinction depends on the measured inputs available during inference, rather than on how the reference diagnosis was assembled. Genuine fusion consumes multiple measured modalities during use; multimodal pre-training followed by image-only inference does not establish that capability.

Does regulatory authorisation establish integrated marrow diagnosis?

No, the reviewed authorisation concerns an assistive digital aspirate application requiring operator verification. It does not establish autonomous synthesis of morphology, flow, cytogenetics, molecular findings and clinical information. The review found no prospectively validated comprehensive marrow system meeting its stated definition of a unified, classification-aligned recommendation.

What should follow retrospective external validation?

The review proposes silent prospective evaluation before live clinical-impact assessment and ongoing surveillance. Silent evaluation records real-time failures and disagreement without affecting care. Subsequent assessment examines diagnostic and workflow outcomes, while surveillance tracks drift and version changes. Case-level multidisciplinary consensus and subgroup analysis are central to the proposed framework.