#Reporting
Incidental prostate adenocarcinoma can be sparse across the many slides made from fragmented prostate chips. Pathologists in Türkiye tested whether a commercial artificial intelligence (AI) algorithm trained on needle biopsies could detect cancer in chips from transurethral resection of the prostate (TURP) and holmium laser enucleation of the prostate (HoLEP). Yeldir et al. reported the results in Diagnostic Pathology on 26 August 2026.
The retrospective study included consecutive cases received at a single institution from May 2023 to December 2025. There were 368 patients, with 247 HoLEP and 121 TURP cases. The investigators analysed 3241 haematoxylin and eosin (H&E) whole-slide images scanned at ×20, including 2466 HoLEP and 775 TURP images.
The algorithm was trained on needle biopsies using weakly supervised multiple instance learning. Technicians ran it as a standalone tool. A case counted as AI-positive if the algorithm flagged at least one slide. Routine light-microscopy diagnosis served as the reference standard, and pathologists did not see the AI output during diagnosis.
Routine microscopy identified 35 cancers, including 26 in HoLEP and 9 in TURP. Overall, the algorithm detected 33 of 35 cancers (94.3% sensitivity). Specificity was 76.0%, positive predictive value (PPV) was 29.2%, negative predictive value (NPV) was 99.2% and accuracy was 77.7%.
In HoLEP, the algorithm detected 24 of 26 cancers (92.3% sensitivity) and falsely flagged fifty-five benign cases. Specificity was 75.1%, PPV was 30.4% and NPV was 98.8%. In TURP, it detected 9 of 9 cancers and falsely flagged twenty-five benign cases. Specificity was 77.7%, PPV was 26.5% and NPV was 100%.
The authors reported a significant rise in malignancy rates as more slides were flagged. The rates were 0.8%, 13.6%, 18.8% and 44.4% for cases with 0, 1, 2 and 3 or more flagged slides, respectively. The paper gives percentages without the underlying counts for each category.
#Interpretation
Both missed cancers were low-volume Grade Group 1 adenocarcinomas in HoLEP specimens, involving about 2% and 5% of the tissue and showing limited atypia. False positives clustered in crowded benign glands, basal cell hyperplasia, adenosis-like change, cautery artefact, stromal fragmentation and inflamed or distorted glands, especially in laser-treated HoLEP tissue.
With a PPV of about three in ten, most flagged cases were benign. The authors suggest using the high NPV to support screening or triage while leaving diagnosis to slide review. They did not measure workload, turnaround time or how pathologists would use the AI output.
The paper reports a case-level area under the curve (AUC) of 0.89 overall. The HoLEP figure legend gives 0.76, and the TURP figure legend gives 1.00 based on only 9 cancers. The paper does not clearly state which score underlies the curves, so the counts are more informative. TURP looked slightly better on sensitivity and specificity, but the authors did not test the difference.
#Limits
The study was retrospective and used a single scanner at one institution. With only 35 cancers and no confidence intervals, estimates by specimen type are uncertain. Five patients had known or strongly suspected cancer before surgery, and the paper does not explain how they were handled in the analysis. It gives no count of excluded cases. The algorithm was not retrained on resection chips.
Five of the eight authors are affiliated with the company that developed the algorithm. The paper declares no competing interests and reports no specific funding.
#Opinion
The high negative predictive value on resection chips is encouraging for triage, but about seven in ten flagged cases were benign and the study included only 35 cancers at one site. In our view, prospective multicentre testing that measures workload, ideally independent of the developer, should come before laboratories rely on the algorithm for triage.
Frequently asked questions
How did the algorithm flag a case?
A single suspicious slide was enough for the algorithm to flag the whole case. Technicians ran the algorithm separately from the diagnostic process. The reference diagnosis came from routine light microscopy, and the pathologists making that diagnosis did not see the AI output.
What did the missed cancers look like?
Both misses were small Grade Group 1 adenocarcinomas in HoLEP specimens with limited atypia. They occupied about 2% and 5% of the tissue. A high negative predictive value therefore did not mean that every cancer was caught, and small, bland foci remained the main source of missed cases.
Did the study show that AI saves review time?
The study did not measure review time or workload. It compared standalone flags with routine diagnoses, so it could quantify how often cases were flagged correctly or incorrectly. That design left open how pathologists would use the flags and whether they would change turnaround time.
Source
https://doi.org/10.1186/s13000-026-01846-z ↗For education and professional reference. This does not give patient-specific advice or replace professional judgement, local protocols or consultation. Editorial standards.