On this page
#Why auditability matters
Mitotic identification contributes to tumour grading and assessment of proliferation. Manual counting takes time and varies between observers. The authors also describe concerns about proprietary AI systems whose training data, preprocessing and decisions are difficult for pathologists to inspect, alongside licensing costs that limit access.
Obami et al., in Journal of Pathology Informatics, 21 September 2026, describe a pipeline developed by researchers in the United Kingdom and Nigeria around an open-source single-stage object detection model. Its purpose is to make whole-slide processing repeatable and each candidate detection traceable for expert review.
#From slide to candidate detections
The pipeline divides a whole-slide image into 512 × 512 pixel tiles with 128 pixels of overlap. The overlap helps retain mitotic figures near tile edges. Tissue gating excludes tiles without sufficient tissue, using a stated threshold of 0.80. Region-of-interest hotspot extraction is combined with denser adaptive tiling in areas of strong mitotic activity.
The model predicts bounding boxes and confidence scores on individual tiles. Coordinates are then translated back to the whole slide. Duplicate suppression at tile and slide levels combines overlapping predictions, retaining the highest-confidence boxes so that overlap does not count the same candidate repeatedly.
Outputs include detection tables with global coordinates and confidence scores, a tile manifest recording tissue fraction and detection count, saved positive overlays, and heatmaps showing detection density. The paper also describes negative overlays among its audit outputs. Runtime logs record tile counts, processing duration and computing-device use. Fixed model checkpoints and documented configurations support repeatability.
#What was run
The authors report processing six whole-slide images, comprising public mitosis benchmark material and blinded clinical slides. The per-slide results are engineering observations, not verified counts of true mitoses.
| Slide description | Tiles | Candidate detections | Mean confidence | Runtime, seconds | Tiles per second |
|---|---|---|---|---|---|
| Public benchmark slide | 5475 | 3003 | 0.893 | 79 | 68.70 |
| Further public benchmark slide | 14,270 | 1754 | 0.923 | 162 | 87.61 |
| Small clinical slide | 26 | 4 | 0.883 | 1 | 20.98 |
| Further clinical slide | 1004 | 65 | 0.888 | 5 | 168.20 |
| Further clinical slide | 829 | 268 | 0.899 | 19 | 42.82 |
| Further clinical slide | 447 | 562 | 0.897 | 5 | 82.34 |
The results text reports average throughput of 78 tiles/s, with a range of 21 to 168 tiles/s. The abstract instead describes average confidence scores between 0.69 and 0.80, which differs from the per-slide values above. The conclusion separately gives throughput of 10 to 50 tiles/s. These inconsistent summaries limit interpretation of a single headline performance estimate.
Quantitative accuracy assessment was confined to annotated patches. The main patch-level results report precision 0.82, recall 0.76 and F1-score 0.79 using bounding-box overlap matching. Centre-point matching gave precision 0.85, recall 0.80 and F1-score 0.82. A figure caption gives different patch-level values, adding reporting uncertainty. Neither set establishes whole-slide accuracy.
#What a pathologist can inspect
Detection tables allow a candidate to be located on the source slide and its confidence examined. Tile manifests show where tissue was processed and where detections arose. Overlays preserve local tissue context for checking individual candidates, and heatmaps show whether candidate hotspots occupy diagnostically relevant regions.
Consultant histopathologists independently reviewed representative tile overlays. They found the visual outputs understandable and identified possible screening or second-reader value, while also highlighting false positives involving inflammatory cells, stromal cells, red blood cells and cytoplasmic fragments. Their feedback supports further refinement rather than clinical readiness.
An audit trail makes errors visible for review and retraining. It does not itself establish that candidates are genuine mitoses or that relevant mitoses have all been found.
#What remains before laboratory reliance
No fully annotated whole-slide reference set was available for the blinded clinical slides. Whole-slide precision, recall and F1-score were therefore not reported. The small slide series and limited expert review restrict generalisation, and the authors state that the model is not yet intended for diagnostic use.
Training and assessment relied largely on public material focused on breast histology. Other tissue types, staining conditions and subspecialties require validation. False positives in low-tissue and difficult regions remain a problem, and the authors propose improved tissue gating, negative-tile handling and training on challenging non-mitotic examples.
Before clinical reliance, the proposed next steps include larger expert-annotated whole-slide cohorts, slide-level benchmarking and larger multi-reader studies. Integration with laboratory information systems remains future work. Single-GPU inference also limits responsiveness and throughput for large cohorts, requiring hardware-aware planning and further scaling work.
The authors declared no known competing financial interests or personal relationships that could have influenced the work, and reported no specific research grant. The practical contribution is an inspectable research workflow whose clinical performance still needs to be established.
Frequently asked questions
Are the reported detections confirmed mitotic figures?
No, whole-slide detection counts are model-generated candidates rather than verified mitotic totals. The clinical slides lacked complete mitosis annotations for comparison. Expert review also identified false positives from several non-mitotic structures, so processing a slide successfully cannot be read as proof that its reported count is diagnostically accurate.
Can a heatmap replace inspection of individual detections?
No, a heatmap summarises candidate density rather than confirming individual mitoses. The pipeline pairs that overview with local overlays and coordinate tables so pathologists can examine candidates in their tissue context. Expert feedback found those outputs understandable, but also exposed errors that require further model refinement and validation.
Does patch-level validation establish performance in other organs?
No, patch-level results do not establish reliable performance across other organs. The authors note that public training material mainly reflects breast histology and may not represent routine diagnostic diversity. Differences in mitotic appearance, tissue architecture and staining require broader datasets and subspecialty-specific evaluation before extending the proposed clinical role.
Source