#Reporting
Du et al., in Frontiers in Medicine, September 2026, report a single-centre retrospective study by researchers in China. It included 54 patients undergoing CT-guided percutaneous lymph node sampling from June 2024 to June 2026.
Samples underwent AI-assisted rapid on-site evaluation (AI-ROSE), conventional exfoliative cytology and histopathology. Histopathology was the reference for the other methods. Smears were prepared from sampled tissue, with remaining tissue fixed for histology. A cytopathologist assessed cytology independently, unaware of the AI results.
The AI workflow locates abnormal cells in digital smear images, extracts suspicious regions and combines image findings into a benign or malignant classification. Operators manually selected high-quality fields before automated reading. Smear preparation, staining and cellularity remained part of quality control.
Histopathology identified 47 malignant and 7 benign lesions. AI-ROSE returned 39 positive, 10 negative and 5 unsatisfactory results. Excluding the unsatisfactory samples left 49 for comparative analysis; all excluded samples were from histologically malignant lesions.
AI-ROSE sensitivity was 90.48% (95% CI: 77.9% to 96.2%), specificity 85.71% and accuracy 89.80% (95% CI: 78.2% to 95.6%). The source text gives conflicting intervals around AI specificity, so no interval is reproduced here. Agreement with histopathology was κ = 0.647 (P < 0.001). McNemar testing found no significant diagnostic bias (χ2 = 0.8, P = 0.371).
Conventional cytology sensitivity was 61.70% (95% CI: 47.4% to 74.2%), specificity 85.71% (95% CI: 48.7% to 97.4%) and accuracy 64.81% (95% CI: 51.5% to 76.2%). Agreement with histopathology was κ = 0.233. These overall cytology estimates included the full cohort, unlike the AI estimates.
Across the 49 satisfactory samples, AI-ROSE and cytology agreed in 77.55%, with κ = 0.482 (P < 0.001), Phi = 0.532 and AC1 = 0.615. Positive agreement was 84.06%, compared with negative agreement of 62.07%.
In the paired malignant subset of 42 samples, positive detection was 90.5% (38/42) for AI-ROSE versus 69.0% (29/42) for cytology (P = 0.012). Agreement in this subset was 73.8%, κ = 0.24; positive conditional agreement was 96.6% and negative conditional agreement 23.1%.
Mean time to results was 235.60 ± 13.88 s for AI-ROSE, 2.27 ± 1.42 days for histopathology and 1.28 ± 0.56 days for cytology.
#Interpretation
The authors position AI-ROSE as an adjunct for immediate adequacy feedback and choices about repeat sampling during lymph node FNA or biopsy. Rapid recognition of suspicious cells could help triage material while definitive tissue assessment proceeds.
This study does not establish replacement of histopathology, reliable lymphoma classification or a reduction in repeat procedures, hospital stay or costs. AI-ROSE cannot supply tissue architecture. Negative findings need caution: its negative predictive value was 60.00%, and disagreement was greater for negative than positive interpretations.
#Limits and disclosures
The authors identify retrospective single-centre design, small sample size and potential selection bias as limits to generalisation. They did not stratify by puncture number, lesion size or lesion subtype, or compare different AI systems or equipment.
Performance depends on fixation, smear thickness, cellularity, necrosis and operator experience. Differences in staining and imaging may affect recognition. The authors call for larger multicentre prospective studies across settings and operator skill levels.
The authors declared no commercial or financial relationships constituting a potential conflict of interest. Funding came from a provincial research foundation and a commercial technology company. They declared no generative AI use in creating the manuscript.
#Opinion
Pathologist's Brief views immediate adequacy feedback as the most useful question for further evaluation. Prospective assessment should retain unsatisfactory samples in the workflow analysis and test whether faster results improve sampling choices while preserving diagnostic oversight.
Frequently asked questions
Were unsatisfactory AI results counted in the reported accuracy?
No, the AI performance analysis excluded unsatisfactory samples. All of those excluded samples were histologically malignant, which matters when interpreting the reported sensitivity and accuracy. Conventional cytology estimates used the full cohort, so the overall figures do not represent identical analysable populations for the competing methods.
Was conventional cytology interpreted with access to the AI result?
No, the cytopathologist assessed conventional cytology without knowing the AI result. This independent reading reduces direct influence from the automated classification on the comparator. It does not remove the study limitations arising from retrospective design, a small single-centre cohort or exclusion of unsatisfactory AI samples.
Did the study prove that AI reduces repeat punctures?
No, fewer repeat punctures were a proposed benefit rather than an established outcome. The study measured diagnostic performance and time to results. The authors describe immediate adequacy feedback as a way to adjust sampling, but prospective workflow evaluation is still needed to establish its practical effects.
Source
https://doi.org/10.3389/fmed.2026.1960803 ↗For education and professional reference. This does not give patient-specific advice or replace professional judgement, local protocols or consultation. Editorial standards.




