# AI classification of haematogones and B-cell acute lymphoblastic leukaemia on blood smear images

> An AI classifier separated benign haematogones from B-cell acute lymphoblastic leukaemia in one internal set of blood smear images. The study could not verify that the test patients were separate from those in training.

Type: Briefing · Topic: Haematopathology
Published: 2026-11-21T10:26:38+00:00
Updated: 2026-11-21T10:26:38+00:00
Canonical URL: https://www.pathologistsbrief.com/article/ai-haematogones-all-blood-smear
Publisher: Pathologist’s Brief
Source: https://doi.org/10.7759/cureus.114985
Author: Editor
Reviewer: Pathologist’s Brief editorial team
Review date: 2026-11-21

## Reporting

Bachir et al., authors in the United States, reported a small retrospective proof-of-concept in [Cureus, August 2026](https://doi.org/10.7759/cureus.114985). The model sorted peripheral blood smear images into four classes: benign haematogones, early pre-B, pre-B and pro-B acute lymphoblastic leukaemia (ALL). The study used labels from a publicly available image dataset. The authors describe these labels as assigned by specialists using flow cytometry.

The authors split 3,208 images approximately 80:10:10 into training, validation and test sets of 2,568, 320 and 320 images, respectively. An automated cloud machine-learning platform chose the model and its training settings. The authors could not inspect either.

On the 320 test images, at a confidence threshold of 0.50, the authors reported average precision of 1.00, precision of 100% and recall of 99.4%. The confusion matrix showed 100% correct classification for haematogones, early pre-B ALL and pro-B ALL. The model correctly classified 98% of pre-B ALL images and called the remaining 2% early pre-B ALL. These were the only reported errors. No haematogone image was called leukaemic, and no leukaemia image was called benign.

## Interpretation

The model performed well on this internal test set. Patient identifiers were unavailable, so images from the same patient could have appeared in both training and testing. Similarities between those images could have inflated performance.

The pre-B and early pre-B errors may reflect overlap in cell appearance, since immunophenotype defines these categories. The study cannot show how the model would handle other leukaemias, reactive states, artefacts or mature blood cells.

## Opinion

The study shows how investigators without advanced programming expertise can build an image classifier with an automated platform. In clinical practice, flow cytometry and expert review distinguish haematogones from lymphoblasts. The authors see AI as a potential aid to that work and say it should complement flow cytometry and expert review.

## Limits

The evaluation used individual images from a single public dataset. It covered only four classes, with no whole-specimen assessment, external validation or comparison with readers. The platform gave no explanation for individual classifications, leaving the authors unable to tell which features drove the predictions.

The paper gives neither per-class test counts nor raw confusion-matrix counts, so the 98% and 2% cannot be converted to numbers of images. The reported precision of 100% is difficult to reconcile with the 2% of pre-B ALL images called early pre-B ALL. The paper does not explain the discrepancy.

The authors declared no funding or competing interests.

## Frequently asked questions

### Did the model mistake any haematogones for lymphoblasts?
No, the study reported no benign haematogone images classified as leukaemic. It also reported no leukaemia images classified as benign. The errors shown in the confusion matrix stayed within the leukaemia categories, with some pre-B ALL images assigned to the early pre-B ALL class.

### Why does it matter whether the training and test images came from different patients?
Images from the same patient in both sets can make the model look more accurate than it is. Similarities between those images may help it classify test images from patients already represented in training. The authors lacked the identifiers needed to check whether the sets shared patients.

### Could the authors tell what the model looked at in a smear image?
No, the platform gave the authors no explanation of what drove individual predictions. The authors could see the assigned classes, but the output could not show whether the pre-B and early pre-B errors reflected cells that looked similar. The paper treats overlap in cell appearance as a possible explanation.